When the high-pressure pump on an RO skid fails, the obvious fix looks like ordering the same model off the nameplate. That works only if the old pump was right for the system you run today. Membranes get swapped, recovery gets changed, the feed water shifts. The pump you need is the one that delivers your feed flow at the pressure your elements need now, survives its own shutoff pressure, and is built from materials your water won't eat. Here is what to check, in the order you would size it.
1. Flow: start from permeate and recovery, not the old nameplate
The pump has to deliver the full feed flow: permeate plus concentrate. Feed flow is permeate flow divided by recovery, so a system making 50 gpm of permeate at 75% recovery needs 66.7 gpm of feed. DuPont's FilmTec manual pairs 70 to 80% recovery with 12 elements in series across two stages of 6-element vessels, and says two stages usually suffice for recovery up to 75%.
Take both numbers from your own log, not from the original design sheet. If the system was re-rated, the old pump may be oversized and spending its life throttled.
2. Pressure: what your elements need, converted to feet of head
Pump curves are drawn in feet of head; RO logs are kept in psi. One psi of water pressure is 2.31 feet of head (the same factor Tigerflow uses in its CD pump manual).
The pump has to supply the difference between what it receives and what the membrane inlet needs, plus the losses in between (piping, valves, the flowmeter). Say your log shows 200 psi at the first vessel, about 10 psi of losses between pump and vessel, and 30 psi at the pump suction after the cartridge filter. The pump must add 180 psi, which is 416 feet of head at 66.7 gpm. That pair, flow and head, is your duty point. Find it on the curve of the pump you are considering.
The element you run sets that pressure more than anything else. NanoH2O rates the BW 400 ES L at 150 psi (10,500 GPD) and the BW 400 R G2 at 225 psi (11,500 GPD), both on 2,000 ppm NaCl at 25°C and 15% recovery. Those are test conditions, not your operating pressure, but they tell you which way your head requirement moves if you change elements. If you are replacing the pump and the membranes in the same shutdown, size the pump for the elements going in, not the ones coming out.
Both NanoH2O brackish elements carry a 600 psi maximum applied pressure, the same limit DuPont gives for brackish elements. The example above runs at 200 psi. The pump has its own maximum operating pressure, separate from the element's; check it as described below.
3. Shutoff pressure plus suction pressure
A centrifugal pump makes its highest pressure at zero flow, the left end of its curve. If a valve closes or the system dead-heads at startup, that shutoff pressure stacks on top of whatever pressure feeds the pump, so the sum has to stay below the pump's maximum operating pressure. Tigerflow's CD manual makes that a rule: supply pressure plus the pump's maximum pressure without flow must always stay below it.
Get the maximum operating pressure for the exact pump model in writing before you order. Then do the arithmetic with your numbers: read shutoff head at zero flow off the curve, divide by 2.31, add your highest suction pressure, and keep the total under that rating.
4. Materials, pH and what the pump must never pump
DuPont's manual says stainless steel is the relevant material for the high-pressure side of an RO system. With concentrate under 7,000 ppm TDS, it calls 316L the minimum for welded pipe and 316 usually acceptable for non-welded parts. Above 7,000 ppm concentrate, it recommends higher alloys (904L, and 254 SMO or similar where crevices occur, including in pumps). So check every wetted part of the pump against the grade DuPont names for your concentrate: 316 at minimum for non-welded parts below 7,000 ppm, 254 SMO or similar above it.
Tigerflow's CD catalog lists 304/316 stainless impellers and body, with a cast iron or 316 head and base depending on construction. Get the wetted materials for the exact model in writing before you order, and hold them against that grade.
The CD manual also limits the pumped liquid to pH 5 to 9. Check your dosed feed pH in your log against that. Cleaning runs far outside it: DuPont's cleaning procedures use solutions at pH 12 and HCl at pH 2, and NanoH2O allows cleaning from pH 2 to 12 on the BW 400 ES L and 1 to 13 on the BW 400 R G2. So clean through a separate cleaning pump, not the high-pressure pump. DuPont says it should be built of 316 stainless or nonmetallic composite polyesters, and recommends 30 to 45 gpm per 8-inch vessel at 20 to 60 psi during high-flow recycle (35 to 45 gpm for fullfit and 440 ft² elements), plus allowance for piping and cartridge filter losses.
5. Suction, minimum flow and startup
- NPSH. The net positive suction head available at the inlet must exceed what the pump requires (NPSHr on its curve). A loaded cartridge filter cuts suction pressure; DuPont lists a low-pressure shutdown switch in the pump suction line as the protection against it.
- Minimum flow. Tigerflow warns against running a CD pump below its minimum flow because of overheating, and says it must never run with the downstream valve closed.
- Soft start. DuPont's startup sequence has the feed valve cracked open before the pump starts, then feed pressure rising by less than 10 psi per second. Faster ramps can telescope elements or crack their shells.
- Speed control. DuPont notes most systems run centrifugal pumps at fixed speed with a discharge throttling valve, and says a variable speed drive should be considered when feed temperature swings more than 5°C (9°F) between low and high.
6. Motor, electrical and fit
Match voltage, phase and frequency to what is wired at the skid, and the motor frame to the pump. Check the brake horsepower at your duty point against the motor: at 66.7 gpm and 416 feet, the water itself needs 7.0 hp (gpm times feet divided by 3,960). Divide that by the efficiency your pump's curve shows at the duty point; at 60%, the shaft needs 11.7 hp. Then check flange type and the port-to-port and base dimensions against your piping, or budget for spool pieces.
Where a Tigerflow CD pump fits
The CD series is a vertical multistage centrifugal pump: up to 570 gpm and 805 feet of head across the range, 2-pole motors (NEMA TC frame, TEFC, per the catalog's specifications), and a cartridge mechanical seal. The example above, 66.7 gpm, sits inside the recommended flow range of three sizes on our pages: the CD10 (26.4 to 74.8 gpm), the CD15 (44 to 127.7 gpm) and the CD20 (57.2 to 154.1 gpm). Enter your own flow and head in the finder on our pumps page; it checks Tigerflow's printed curves and opens the size that fits, with your point drawn. Then run the shutoff check and the materials check above on the model it lands on. We are an authorized Tigerflow distributor. Every CD model is listed with its Tigerflow part number and list price; send the model and quantity and we reply with your price and freight. CD pumps usually ship in about 5 days, plus transit time.
Have your duty point (feed flow, required pressure rise, suction pressure, voltage and phase) ready, then find your CD model and request it. Replacing elements in the same shutdown? See the BW 400 ES L and BW 400 R G2, priced on the page, and ask Crystal Claire, our sales engineer in the site chat, for help choosing.
Sources
- FilmTec Reverse Osmosis Membranes Technical Manual, Form 45-D01504-en Rev. 20, DuPont (sections 3.5, 3.14, 3.15, 5.2.3, 6, Tables 25, 30, 36)
- BW 400 ES L product data sheet D-BW400ESL-EN-093026, NanoH2O
- BW 400 R G2 product data sheet D-BW400RG2-EN-093026, NanoH2O
- CD Series catalog 2023, Tigerflow
- CD pumps installation, operation and maintenance manual, Tigerflow
- CD Series, Tigerflow